If your double check valve backflow preventer fails—or isn't certified for local code—you risk contamination lawsuits, system downtime, and costly retrofits. Purchasing managers and facility engineers we work with report these top frustrations:
Our double check valve backflow preventer assemblies are manufactured in our Hebei factory under strict ISO 9001 quality management. Every unit is hydrostatically tested and certified to meet international backflow standards. Here's why US and European buyers choose Thriveon:
Optimized flow path reduces pressure drop by up to 35% compared to standard models. Saves pumping energy over the life of the system.
Bronze or ductile iron body with fused epoxy coating. Stainless steel springs and check seats. Resists aggressive water chemistry.
NSF 61 / NSF 372, ASSE 1015, USC FCC&CHR, and UL/FM pending. Meets AWWA C510. Full documentation package included.
Stock sizes ¾"–2" ship in 7–12 days. Custom flanged connections (2½"–10") in 18–25 days. OEM / private label available.
Equipped with ball valve test cocks (NPT threads). Easy access for annual testing and in-line maintenance without removal.
Each assembly passes hydrostatic shell test at 300 psi and seat leakage test at 80 psi. Test report shipped with every order.
| Parameter | Available Range / Details |
|---|---|
| Size (inch) | ¾", 1", 1¼", 1½", 2", 2½", 3", 4", 6", 8", 10" |
| End Connections | Threaded (NPT / BSP) ¾"–2" · Flanged (ANSI 125/150) 2½"–10" · Grooved (option) |
| Maximum Working Pressure | 175 psi (12 bar) standard · 250 psi (17 bar) on request |
| Temperature Range | 32°F – 180°F (0°C – 82°C) · Higher temp upon request |
| Body Material | Bronze (C84400) · Ductile Iron (ASTM A536, epoxy coated) · Stainless Steel 316 (option) |
| Trim / Seats | Noryl® / PTFE / EPDM · Stainless steel 304/316 springs |
| Certifications | NSF 61 · NSF 372 (lead-free) · ASSE 1015 · AWWA C510 · USC FCC&CHR · ISO 9001 · CE · RoHS |
| Testing | 100% hydrostatic shell test · 100% seat leakage test · Certified test report included |
dual check valve backflow preventer double check valve backflow prevention double check backflow valve
📌 Application examples: Commercial building water mains · fire sprinkler system risers · irrigation sub-meters · industrial process water isolation · boiler feed lines. Request a sizing recommendation →
David M. · Plumbing Specifier, R.G. Vanderweil Engineers
Sarah K. · Procurement Manager, City Water Authority
Tomás R. · Director of Operations, FireSafe Systems
A double check valve assembly (DCVA) uses two independently operating check valves to prevent backflow under non-health-hazard (low to moderate hazard) conditions. An RPZ includes a differential pressure relief valve and is required for high-hazard (health hazard) applications. Most commercial fire and irrigation systems use DCVA. Always consult local codes — we can help you choose the right assembly.
Yes. Our DCVAs carry NSF 61 (drinking water) and NSF 372 (lead-free) certification, and are listed by ASSE 1015. We also comply with AWWA C510 and USC FCC&CHR standards. UL/FM listing for fire protection models is in process — contact us for current certification status for your specific model.
For standard sizes (¾"–2" threaded), MOQ is 10 units for stock models. For larger flanged sizes (2½"–10"), MOQ is 5 units. OEM/private label orders with custom packaging and branding require a minimum of 50 units. We also offer sample orders (1–2 units) at sample price for qualification/testing.
For stock sizes, we ship within 7–12 business days. Air freight (DHL/FedEx) reaches US east coast in 4–6 days. Sea freight (FOB Tianjin or CIF to your port) takes 18–28 days depending on destination. We also offer express shipping with real-time tracking. Contact us for a quote on your specific delivery address.

Absolutely. We provide full OEM and ODM services: custom body casting with your logo, custom packaging, special coatings, and non-standard connection sizes. Our engineering team will work with your specs. Lead time for OEM orders is typically 25–35 days after drawing approval. Start your OEM inquiry →
We accept T/T (bank transfer), L/C at sight, and Western Union for new customers. For established relationships and larger orders, we offer 30% deposit + 70% against copy of B/L. PayPal is available for sample orders. We also provide trade assurance for eligible transactions.
Yes. Every double check valve backflow preventer carries a 2-year warranty against manufacturing defects. Our in-house engineers (10+ years of valve design experience) provide free technical support via phone, email, and WhatsApp. We also stock common repair parts and can ship them urgently.
Get factory-direct pricing, free samples for qualified projects, and technical documentation tailored to your local code. Limited-time: free expedited shipping on first orders over $2,000.
✓ No minimum for sample orders ✓ 2-year warranty ✓ 100% factory tested ✓ Technical support in English
James L. · Mechanical Engineer, AECOM
Maria F. · Supply Chain Director, Western Plumbing Supply
Robert H. · Fire Protection Consultant, CodeSafe LLCRelated Products
Call us on:
+86-311-86935302
+86-311-86935302
Email Us:
info@thriveonvalve.com
South of Huanmadian Village Town, Ningjin County, Xingtai, Hebei Province, China